Inability to reach Setpoint

From the choices you have made the problem you are experiencing
is most likely to be caused by problems with :

The most likely causes are: Remedial Actions after overhaul are:
  • Blocked nozzles
  • Incorrect Air/Gas mixture
    (Lean at max fire)
  • Incorrect control loop tuning
  • Expected heat loss/gain
    too large for
    capacity of zone
  • Sensor fault
    (purge air too high)
  • Thermocouple too deep
  • Thermocouple out of glass
  • Excessive crossover
  • Max Fire pressure
    too low
  • Clean Nozzles
  • Check/Adjust
    Air/Gas Ratio
  • Re-tune Loops
  • Adjust Setpoints in all zones

  • Check/Adjust purge air

  • Reset TC Height
  • Reset TC Height
  • Adjust crossover setting
  • Check and adjust
    high max fire