Oxy Fuel Burner Manifold
Oxy-Gas
400 Series Title

    Features

    • High heat input
    • High turndown ratio
    • Concentrated sidewall heating
    • Low volume of combustion Products and reduced volatilisation
    • Integrated safety features
    Benefits

    • Improved thermal Homogeneity
    • Faster responses
    • Increased glass throughput
    • Improved glass quality
    • Longer superstructure refractory life with volatile glasses


    The BH-F/BOC Oxy-gas forehearth has now been proven for high temperature applications

    The forehearth was developed by BH-F (Engineering) Ltd and BOC Gases with the assistance of Corning Incorporated.
    It has been designed to provide highly controllable heating of the side glass in a forehearth
    Without the high levels of combustion products that affect centre glass temperatures and internal forehearth pressure.
    The result is a more responsive forehearth that delivers higher throughput, better thermal homogeneity and improved glass quality with less refractory damage.


    TECHNICAL DATA

     

    Glass Type

       

    Suitable for most glass types

    Roof Blocks

    Design

    400 series design.

     

    Material

    To suit glass type

    Glass Contact Blocks

    Design

    As conventional forehearths

     

    Material

    To suit glass type

    Burner blocks

    Design

    Modified forehearth K type burner block

     

    Materials

    Special High Alumina

    Burner nozzles and manifolds

    Nozzle Design

    Patented nozzle mix burner

     

    Capacity

    0.3 to 3.6kW
    (1,000 to 12,000 Btu/hr)

     

    Burner centres

    114mm (4.5 inches) - Standard

     

    Manifold Design

    Linked gas and oxygen
    manifolds on
    quick withdrawal brackets

    Combustion pipework

    Gas

    Mild steel with threaded joints

     

    Oxygen

    Copper with
    silver soldered joints

    Combustion Controls

    Gas and
    Oxygen Controls

    Motorised adjustable
    port valves

     

    Measuring devices

    Mass flow meters

     

    Safety Standard

    To BS EN 746-2: 1997

    Process Control

    Main Control loops

    Zone temperature control

     

    Secondary
    Control loops

    Gas flow,
    oxygen flow
    and ratio control

     

    Interlocks

    Ratio limiting

    Service Requirements

    Combustion gas

    Natural gas

     

    Oxygen

    90% purity or better

     

    Power Supply

    110-240V,
    single phase,
    50-60 Hz

     

    Environment (Panel)

    -20° C to 60° C
    (-4° F to 140° F)