Glass Type |
|
Suitable for most glass types |
|
Roof Blocks |
Design |
400 series design. |
| |
Material |
To suit glass type |
|
Glass Contact Blocks |
Design |
As conventional forehearths |
| |
Material |
To suit glass type |
|
Burner blocks |
Design |
Modified forehearth K type burner block |
| |
Materials |
Special High Alumina |
|
Burner nozzles and manifolds |
Nozzle Design |
Patented nozzle mix burner |
| |
Capacity |
0.3 to 3.6kW (1,000 to 12,000 Btu/hr) |
| |
Burner centres |
114mm (4.5 inches) - Standard |
| |
Manifold Design |
Linked gas and oxygen manifolds on quick withdrawal brackets |
|
Combustion pipework |
Gas |
Mild steel with threaded joints |
| |
Oxygen |
Copper with silver soldered joints |
|
Combustion Controls |
Gas and Oxygen Controls |
Motorised adjustable port valves |
| |
Measuring devices |
Mass flow meters |
| |
Safety Standard |
To BS EN 746-2: 1997 |
|
Process Control |
Main Control loops |
Zone temperature control |
| |
Secondary Control loops |
Gas flow, oxygen flow and ratio control |
| |
Interlocks |
Ratio limiting |
|
Service Requirements |
Combustion gas |
Natural gas |
| |
Oxygen |
90% purity or better |
| |
Power Supply |
110-240V, single phase, 50-60 Hz |
| |
Environment (Panel) |
-20°
C to 60°
C (-4°
F to 140°
F) |